11 research outputs found
The KATRIN Experiment
The KArlsruhe TRitium Neutrino mass experiment, KATRIN, aims to search for
the mass of the electron neutrino with a sensitivity of 0.2 eV/c^2 (90% C.L.)
and a detection limit of 0.35 eV/c^2 (5 sigma). Both a positive or a negative
result will have far reaching implications for cosmology and the standard model
of particle physics and will give new input for astroparticle physics and
cosmology. The major components of KATRIN are being set up at the Karlsruhe
Institut of Technology in Karlsruhe, Germany, and test measurements of the
individual components have started. Data taking with tritium is scheduled to
start in 2012.Comment: 3 pages, 1 figure, proceedings of the TAUP 2009 International
Conference on Topics in Astroparticle and Underground Physics, to be
published in Journal of Physics, Conference Serie
The design, construction, and commissioning of the KATRIN experiment
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [1] to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90% C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating [2]. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times, and present details on their respective commissioning campaigns
Recommended from our members
The design, construction, and commissioning of the KATRIN experiment
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [1] to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90% C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating [2]. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times, and present details on their respective commissioning campaigns